<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-18 16-00-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.90 MHz 5/5, 40 dBuV CAMPUS
Pilot RDS Phase Difference
6.7 kHz 3.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 16 kHz 9445 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
-8,2 dBr -8,20 dBr -8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" CAMPUS " FEA3 0 (No PTY) 0 0 1 1 16:02, 25.04.1984
RT
-
AF EON
93.9 MHz -
FM Scope Station: 93.90 MHz, signal: 5/5 (40 dBuV) Max at: 16 kHz MIN: 12 kHz % above 75 kHz: 0,0000 Acquired: 2025/07/18 15:59:36 Total samples: 9445 Equivalent time: 0:07:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: -8,2 dBr MIN: -8,2 dBr AVE: -8,20 dBr % above 10,2 dBr: 0,0 Last value: -8,2 dBr (2025/07/18 15:59:35) Station: 93.90 MHz, signal: 5/5 (40 dBuV) 15:53 15:54 15:55 15:56 15:57 15:58 15:59 0 50 100 Dev. MAX [kHz] -5 0 Pm [dBr] 0 5 Signal Quality